Search

CZone COI

CZone COI

HTML Editor - Full Version

Digital Switching, Let CZone do the thinking.  Control your boat or RV easily from anywhere.

The CZone digital control and monitoring network simplifies installation of electrical systems through the replacement of complicated wiring. CZone replaces switch and fuse panels with state-of-the-art, robust interfaces and light NMEA 2000 network cables. It provides a sophisticated solution via automation of the control and monitoring issues required by today’s complex on-board and in-vehicle systems.

CZone allows the user to control multiple circuits with “One Touch”, dramatically simplifying operation. With control potentially available at any point in the NMEA network, fingertip control is available anywhere around the boat or vehicle, through the dedicated CZone screens, iPad, remote keyfob or through the navigation MFDs of integration partners.

Ease of operation assured. With one press of the key users can turn on a group of circuits without having to search for them and turn on the individual circuits that they need for the operation of their vessel or vehicle. When leaving, simply press ‘systems off’ to turn off all non-essential circuits. Entertainment mode allows preset activation of lounge lights, music, etc. All functions can be controlled remotely.

The CZone system, designed for 9V to 32V systems, features built-in timers, dimmers (including support for halogen lighting), alarms, voltage reducers and load shedding. With safety in mind, the CZone™ system features a manual bypass.

Code Image Product Details Enquire
80-911-0119-00
CZone COI
Combination Output Interface with Connectors
80-911-0120-00
CZone COI
Combination Output Interface no Connectors
80-911-0131-00
CZone COI
Control 1/COI Duetsch Connector Kit
80-911-0134-00
CZone COI
COI Digital Switch Breakout 6 Way
80-911-0136-00
CZone COI
COI Digital Switch Breakout 6 Way

TOTAL CHANNELS

30 Channels

OUTPUT CHANNELS HIGH

4 x 25A

OUTPUT CHANNELS LOW

12 x 10A Dimmable

ANALOGUE INPUTS

8 x Analogue Inputs: Positive or Negative Switching, 0-32 Volt, 0-1000 Ohm

Resistance & 4-20mA Current

ADDITIONAL MONITORING

2 x Voltage Sensors (Main Positive Stud & NMEA2000 Power)

DIGITAL SWITCH INPUTS

6 x Digital Inputs w Systems On/Backlighting via Digital Breakout

CIRCUIT CURRENT MONITORING

All 16 Output Channels

CIRCUIT PROTECTION

Configurable Electronic Fuse + Mechanical Fuse & Bypass

MAXIMUM CONTINUOUS CURRENT

150 @ 40°C (derated above 40°C)

NMEA2000 POWER CONSUMPTION

250mA @ 12V, 180mA @ 12V standby

CONNECTORS

Deutsch

POWER SUPPLY

M8 (5/16”) Stud Positive, M6 (1/4”) Negative

VOLTAGE

9-32V (with Power Available LED and Voltage Monitoring)

BILGE PUMP CIRCUITS

4 x High Current Channels: Integrated manual control & pump running detection

INGRESS PROTECTION

IPx5 (mounted at 0°, +/-90°)

COMMUNICATION

NMEA 2000

CERTIFICATION

CE, ABYC, NMEA